Furnace, Boiler and Water Heater Flue Relining
When the oil burner goes or the new furnace vents out the wall, the old chimney is suddenly the wrong size for what is left on it. A stainless liner sized to the remaining appliances typically runs $2,100 to $3,800.
Drive through Levittown and most of the houses you pass heat with oil. The Census Bureau's 2024 American Community Survey puts fuel oil at 60 percent of Levittown homes, against 3.5 percent nationally, and the share stays high across the outer suburbs: about 36 percent in Pottstown and in Ephrata, 31 percent in Kennett Square, and roughly one home in five across Bucks and Berks counties. Every one of those boilers sends its exhaust up a chimney, usually a masonry flue built for a big, hot oil burner, and often with the water heater tied into the same passage.
That works until something changes. Owners switch from oil to gas, replace the boiler with a high-efficiency model piped through a side wall, or add a water heater. Each change leaves the chimney carrying less heat than it was built for, and a cool, oversized flue is where condensation and backdraft begin. Relining puts a stainless pipe inside the old masonry, sized to what still vents there.
When to call
- The furnace or boiler was replaced and now vents out the side wall
- You switched from oil to gas and nobody looked at the chimney
- Rusty water dripping at the cleanout or the base of the flue
- White salt stains or damp patches on the chimney in the basement or attic
- Bits of clay tile or mortar collecting in the cleanout
- A CO alarm that chirps or sounds when the heat or hot water runs
The visit, step by step
- Trace every flue, freeWe follow each passage from the appliance to the top, note what connects where, and photograph the cleanout, the connector and the crown.
- Size the liner to what staysThe diameter comes from the appliances that will keep using the chimney and the height of the stack, not from the size of the old masonry opening.
- Examine and clear the passageOil soot, fallen tile and debris come out before a gas appliance is connected, which the 2021 IRC asks for in any chimney that used to vent oil or wood.
- Install, connect and testThe stainless liner runs from the connector to a new top plate and cap. We check draft with the appliances running and leave you a note of what the flue now serves.
Why switching from oil to gas changes the chimney
An oil boiler sends hot exhaust up a flue sized for that heat. Gas burns cleaner but makes more water vapor, and modern gas appliances run cooler. In a passage that is too big, the vapor condenses on the tile before it reaches the top, and over a few winters that acidic water eats at the joints and flakes the tile.
Pennsylvania has used the 2021 International Residential Code since January 1, 2026, and it speaks to exactly this. Sections M1801.3 and G2425.15 say that once an appliance is taken off an existing chimney for good, or a new one is hooked up, the flue has to be resized wherever needed so exhaust condensation stays in check and whatever is still connected keeps a good draft. Section G2427.5.5 adds that before a gas appliance is hooked to a chimney, the passage has to be examined, and cleaned if it previously vented a solid or liquid fuel.
UGI's gas conversion page covers the service line and meter but not the chimney, which is why the flue so often gets missed.
The water heater left behind
A common oil-belt story goes like this. The old boiler and the water heater shared one chimney. The boiler is replaced by a sealed, high-efficiency unit that vents out the wall. Now the water heater is the only user of a flue built for two appliances, sending a thin stream of lukewarm exhaust into a big, cold passage.
That weak draft is easy to overpower. A kitchen fan, a dryer or a cold, windy night can stall it, and exhaust spills out of the draft hood into the basement. Section G2425.15.1 exists for this case. Most often we fix it with a stainless liner matched to the water heater on its own, run the full height and capped. If the water heater is moving to a sidewall vent too, the better answer may be to cap the empty flue, and we will say so.
Rowhouse heater flues in Philadelphia
Inside the city, heating fuel is mostly gas, about 70 percent of homes per the Census, but the chimneys are old. Four in ten Philadelphia homes were built before 1940, and 56 percent are rowhouses, twins or townhouses. A rowhouse stack can hold several flues side by side, one of them usually the heater flue, so we trace every passage and document which one serves which house.
The other city risk sits above the roof. When the house next door adds a floor and your heater flue ends up below its new wall, L&I warns of increased fire risk and potential carbon monoxide poisoning. Community Legal Services described a Graduate Hospital client whose neighbor built a third floor; PGW later found elevated CO at her furnace and shut off her gas, and her chimney had been sealed with plywood and tar. CLS won a $4,600 judgment in May 2026. Our rowhouse chimney page explains the city rule.
In a historic district, the top of the flue matters too. The Historical Commission's Diamond Street manual says metal B-vents sticking out of chimneys are not approved there and suggests terra cotta liners or a metal liner cut below the brick. A stainless liner that ends beneath a low cap fits that approach, and if staff review applies, we pull the photos and scope together with you.
Two appliances, one flue: what the code allows
Gas appliances can sometimes share a correctly sized flue. A wood fireplace or stove cannot share with anything. Section M1801.12 says a solid fuel-burning appliance or fireplace shall not connect to a chimney passage venting another appliance, and G2427.5.6.1 says the same from the gas side. R1003.12.2 adds that the space left around a liner cannot be used to vent a second appliance. In practice:
- A gas furnace and a gas water heater may share one liner only when it is sized for both together.
- A furnace flue that also serves a working wood fireplace has to be split, so each gets its own passage.
- The gap between a new liner and the old tile is never a second vent.
- Whenever an appliance comes off the chimney, the size of what remains gets checked again.
Carbon monoxide: what PGW, PECO and UGI tell customers
All three gas utilities in our area give the same first instruction for a gas smell: leave, then call from outside. PGW's 24-hour emergency line is 215-235-1212. PECO, at 800-841-4141, asks you to get at least 100 feet away before calling. UGI customers can call 800-276-2722, or 911, once they are well clear of the house. Don't flip switches or try to shut valves on the way out.
Carbon monoxide has no smell. UGI lists condensation on windows, headaches, dizziness and flu-like symptoms as warning signs, and says a damaged or blocked chimney can let exhaust, CO included, into the home. PGW asks customers to have appliances, chimney and flue serviced regularly and to replace CO detectors every five years. PECO notes that a gas detector is not a CO detector. If anyone may have CO poisoning, call 911.
Cost, timing and permits
A stainless furnace or boiler liner typically runs $2,100 to $3,800 installed in 2026, the range a Philadelphia-area company publishes for this work. Where your job falls depends on the chimney's height, the number of offsets, how much debris has to come out first, and whether the top needs a new plate and cap. Checking the flue costs nothing, and you see a written price before any work.
Most liners go in within a day. Replacing or adding the appliance takes a mechanical permit in Philadelphia; elsewhere we check what your township or borough requires before we start.
Answers
Furnace, Boiler & Water Heater Flues questions
We switched from oil to gas. Does the chimney need a liner?
It needs at least a look and a clearing. The 2021 IRC asks that a chimney be examined before a gas appliance is connected, and cleaned if it vented oil before. Whether it also needs a liner depends on how the old flue compares with the new appliance, and we measure that at the free flue check.
The new furnace pipes its exhaust out a side wall. Is the water heater left in the chimney a problem?
Often, yes. A lone water heater in a flue sized for a furnace and water heater together can drift into weak draft and condensation. Code calls for resizing the chimney when an appliance is disconnected, and in practice that tends to mean a stainless liner matched to the water heater.
Can my fireplace and furnace share one flue?
No. Under M1801.12 a wood fireplace or stove cannot connect to a passage that vents another appliance, and G2427.5.6.1 says the same for gas appliances. If they share now, one of them needs its own flue or liner.
How much does relining a furnace or boiler flue cost?
A stainless furnace or boiler liner typically runs $2,100 to $3,800 installed in 2026. Height, offsets and how much old debris is in the flue set the final number, which you get in writing at the free flue check.
How often should a gas furnace or boiler flue be checked?
Once a year. PGW asks customers to have appliances inspected by a professional at least yearly and the chimney and flue serviced regularly. Oil flues build soot faster and should be looked at every year as well.
The CO alarm is sounding. What now?
Everyone outside first; if someone feels ill, dial 911. For a gas smell, call your utility from outside. Once the house is safe, we can find out why the flue failed.